PT Turn Ratio Meter Calibration Transformer Testing Equipment Dengan Pengiriman Cepat

Rincian produk

Tempat asal: Hubei, Tiongkok

Nama merek: GDZX

Sertifikasi: ISO9001

Nomor model: ZXCBB

Syarat Pembayaran & Pengiriman

Kuantitas min Order: 1 set

Harga: $15,000.00 - $20,000.00 / Sets

Kemasan rincian: Kotak karton atau kayu

Waktu pengiriman: 7 ~ 10 hari kerja

Syarat-syarat pembayaran: L / C, D / A, D / P, T / T, Western Union, MoneyGram

Menyediakan kemampuan: 1200 Set / set per Tahun

Dapatkan Harga Terbaik
Rincian produk
Menyoroti:

instrumen uji transformator

,

mesin uji transformator

Nama Produk:
Peralatan Kalibrasi PT Turn Ratio Meter Dengan Pengiriman Cepat
Bobot:
10kg
Tampilan:
LCD
Jaminan:
1 tahun
Nama Produk:
Peralatan Kalibrasi PT Turn Ratio Meter Dengan Pengiriman Cepat
Bobot:
10kg
Tampilan:
LCD
Jaminan:
1 tahun
Deskripsi Produk

The equipment is used to test the turn ratio accuracy, resolution and group ( including Z type) of the instrument transformer turn ratio testers with accuracy at 0.5 or below 0.05. Peralatan tersebut digunakan untuk menguji akurasi rasio putaran, resolusi dan kelompok (termasuk tipe Z) dari penguji rasio turn transformator instrumen dengan akurasi 0,5 atau di bawah 0,05. It is composed of two parts: standard three phase PT and inductive voltage divider. Ini terdiri dari dua bagian: standar tiga fase PT dan pembagi tegangan induktif. The PT is used to test ratio group test function of the ratio tester, inductive voltage divider is used to test the accuracy and resolution of the ratio tester PT digunakan untuk menguji fungsi kelompok uji rasio dari tester rasio, pembagi tegangan induktif digunakan untuk menguji akurasi dan resolusi rasio tester

 

Indikator teknis

Tegangan primer 200V
Tegangan sekunder 0 ~200V
Nilai beban 0VA
Akurasi pembagi tegangan induktif 0,0005%
Perbandingan kamuKetidakpastian 3 ×10-6
Bobot 10Kg
Akurasi standar tiga fase PT 0,05%

 

Parameter

1. Putar tes rasio dengan pembagi

Turns ratio range can be preset as the reciprocal of any value during 1.111111~0.0000001. Kisaran rasio belokan dapat ditetapkan sebagai kebalikan dari nilai apa pun selama 1.111111 ~ 0.0000001. When turns ratio is 1,2,5,10,20,50,100,200,500,1000,2000,2500, the dial scale of the inductive voltage divider should be selected as 1.000000,0.5000000,0.2000000,0.1000000,0.0500000,0.0200000,0.0100000,0.0050000,0.0020000,0.0010000,0.00050000,0.00040000. Ketika rasio belok adalah 1,2,5,10,20,50,100,200,500,1000,2000,2500, skala panggil pembagi tegangan induktif harus dipilih sebagai 1,000000,0,5000000,0.2000000,0.1000000.0.0500000.0.0200000.0.0100000.0.0050000, 0,0020000,0,0010000,0,00050000,0,00040000. UAX rated voltage is 200V, it can work under 20%~100% of rated voltage. Tegangan pengenal UAX adalah 200V, dapat bekerja di bawah 20% ~ 100% dari tegangan pengenal.

 

2. Tes resolusi

Usually set the divider value during 0.1000000~0.0999900 which mean turn ratio to be 10.000~11.100. Biasanya mengatur nilai pembagi selama 0,1000000 ~ 0,0999900 yang berarti rasio giliran menjadi 10.000 ~ 11,100. The display value of the ratio tester should obviously change when the divider set value changes. Nilai tampilan penguji rasio harus jelas berubah ketika nilai yang ditetapkan pembagi berubah.

 

3. tes langsung

It means the test when divider set value is 1.000000. Ini berarti tes ketika nilai pembagi yang ditetapkan adalah 1,000000. When make this test, the primary UAB will be directly connected with secondary terminal ( a, b terminal), that is to say, UAB=Uab. Ketika melakukan tes ini, UAB primer akan langsung terhubung dengan terminal sekunder (a, b terminal), artinya, UAB = Uab. It is 1/1 self-checking. Ini 1/1 memeriksa sendiri. But when the ratio tester is the type for which such straight test are not allowed, inductive isolated winding can be used to do 1/1 isolation test. Tetapi ketika penguji rasio adalah tipe yang uji lurusnya tidak diizinkan, belitan terisolasi induktif dapat digunakan untuk melakukan uji isolasi 1/1.

 

3. Uji kelompok rasio

The standard three phase PT can make 12 groups for group testing of the ratio tester. Tiga fase standar PT dapat membuat 12 kelompok untuk pengujian kelompok dari tester rasio. Turns ratio can be 10 or 100 or 1000 total 3 choices. Rasio putaran bisa 10 atau 100 atau 1000 total 3 pilihan. PT each single phase error less than 0.05% PT setiap kesalahan fase tunggal kurang dari 0,05%

 

4. Tes kelompok tipe Z

Total 10 kelompok (/ Z atau Y / Z) untuk tipe Z, rasio putaran menjadi 100. PT setiap fase kesalahan berliku sekunder kurang dari 0,05%